The goal is not just to quantify vibration levels, but to pinpoint their root cause and recommend specific corrective actions. Our vibration analysts hold ISO 18436‑2 Category III certification.
Scope
What we offer
We work with data from online monitoring systems as well as our own on-site measurements taken with portable instruments. Every diagnosis ends with a report setting out our findings and recommendations.
- Spectrum and phase analysis
- Shaft orbits and shaft centreline position
- Run-up and coast-down analysis
- Post-overhaul and acceptance diagnostics
- Analysis of online monitoring data
- Report with findings and recommendations
When to call us
Typical symptoms
Rising vibration
The trend keeps climbing with no obvious process cause.
Alarms and trips
Protection trips or frequent alarms from the MMS.
Vibration after an overhaul
The machine runs worse after the overhaul than before it.
Start-up problems
High vibration when passing through critical speeds.
Bearing noise and temperature
Unusual noise or rising bearing temperatures.
Spectrum changes
New components in the spectrum or a shift in 1X phase.
Recognise one of these symptoms? An analyst will help find the cause.
Analysis tools
Methods and analyses
Spectrum analysis
Identifying frequency components and tracing their sources.
Phase and orbit analysis
Assessing shaft motion, unbalance, misalignment and looseness.
Transient analysis
Bode, polar and waterfall plots from run-ups and coast-downs.
Trends and process correlation
Relating vibration to load, temperature and operating parameters.
Process
How we work together
- 01
Request
Problem description, machine data, available measurements.
- 02
Data review
Review of trends and MMS data, where available.
- 03
On-site measurements
Supplementary measurements, including transient conditions.
- 04
Diagnosis
Identifying the root cause of the vibration.
- 05
Report and recommendations
Findings, recommended actions and support in carrying them out.
From the field
Projects
Wind / renewables · 2017–2026
PGE wind farms: online monitoring and bearing diagnostics
PGE Energia Odnawialna, wind farms, Poland
- Vibration diagnostics
- Online condition monitoring
- Vibration measurements
Heavy industry & manufacturing · 2024
Recurring fan bearing failures at a cement plant
Cement plant, Poland
- Vibration diagnostics
- Laser shaft alignment
- Vibration measurements
Mining · 2024
Trim balancing of fans at a coal mine
Coal mine, Poland
- Machine balancing
- Vibration measurements
- Vibration diagnostics
Power generation · 2024
Start-up vibration measurements after a turbine overhaul
Power plant, Hungary
- Vibration measurements
- Vibration diagnostics
Related projects
2026
TAURON, Czchów hydropower plant · Poland
Coupling alignment checks on the flap gate drives during their modernisation.
2026
TAURON, Otmuchów hydropower plant · Poland
Independent vibration measurements on a hydro unit before its overhaul, as reference data for the overhaul.
2026
ORLEN Termika – Żerań CHP · Poland
Assessment of the dynamic condition of turbine set TZ13 under the protection-systems frame agreement.
2026
ORLEN Termika Silesia, Wodzisław Śląski · Poland
Diagnostics of 11 fans in Wodzisław and 4 at the Niewiadom branch, with balancing, alignment and acceptance.
2026
ORLEN Termika Silesia – Żory and Czerwionka-Leszczyny · Poland
Diagnostics and service of 14 fans at two plants, including acceptance for operation.
2026
ORLEN Termika Silesia, Wodzisław Śląski (formerly PGNiG Termika EP) · Poland
Diagnostics of 11 fans with balancing, alignment and acceptance for operation.
2025
Enefit – Balti Power Plant · Estonia
Dynamic condition of the LMZ K-200-130 turbine set, unit 11, analysed during overhaul and start-up, with recommendations.
2025
Bhotekoshi Power Company · Nepal
Vibration data of a 22.5 MW turbine-generator analysed: condition, recommendations and expected remaining service life.
Related services
Typical machines
Other rotating machinery — e.g. wind turbines, gearboxes. Ask us →
Frequently asked questions
Didn't find your answer? Ask an engineer →
How long does vibration diagnostics of industrial machinery take?
Basic vibration measurements and an initial assessment of the problem are usually completed in a single site visit. Diagnostics of turbines, compressors, pumps and other critical rotating machines may require spectrum and phase analysis and measurements at different loads. When the report is delivered depends on the scope of the work.
Can vibration diagnostics be carried out without stopping the machine?
Yes. We usually measure vibration on rotating machinery during normal operation, as this shows how the machine behaves under real operating conditions. Where justified, measurements during run-up, coast-down or load changes are also needed. Safe access to the measurement points is agreed with the plant.
What faults can vibration diagnostics detect?
Vibration analysis helps identify the symptoms of rotor unbalance, misalignment, mechanical looseness, bearing damage, gearbox problems and some resonance phenomena. For turbines and compressors we also take rotor dynamics and the influence of process parameters into account. A final assessment requires the data to be interpreted in the context of the specific machine.
Is vibration spectrum analysis enough to establish the cause of a failure?
Not always. Spectrum analysis is the foundation of vibration diagnostics, but similar symptoms can have different causes. That is why we combine frequency analysis with phase measurements, vibration trends, operating data and, where needed, run-up or coast-down characteristics. This reduces the risk of a wrong diagnosis.
What does a machine vibration diagnostics report contain?
Depending on the agreed scope, a vibration report contains the measurement results, spectra and vibration characteristics, an assessment of the machine's condition and a description of the abnormalities found. We also give conclusions and recommendations on continued operation, further testing or service work. For critical machines, comparison with earlier measurements is important.
What are the most common causes of high vibration in rotating machinery?
High vibration in rotating machinery can result from unbalance, shaft misalignment, mechanical looseness, bearing damage, resonance or unstable process conditions. In turbines and compressors, rotor-dynamic phenomena also play a part. The cause is determined from vibration spectra, phase and trends together with operating parameters. A rise in the overall vibration level alone does not point to a single fault.
How can rotor unbalance be recognised from vibration measurements?
Rotor unbalance often shows up as an increased 1X component, i.e. vibration at the rotational frequency. The direction and phase of the vibration and how it responds to speed changes also matter. However, other faults can produce a similar picture. That is why, before balancing, we compare the measurement results with the machine's design, its history and its behaviour at different loads.
How can shaft misalignment be recognised from vibration analysis?
Misalignment may be accompanied by increased axial and radial vibration and by 1X and 2X components. This pattern alone, however, does not confirm an alignment fault. Diagnostics looks at spectra, vibration phase, temperatures and the loads on the machine train, and the result is verified by an alignment measurement. This makes it possible to tell a shaft alignment problem apart from unbalance, looseness or coupling damage.
What does an increase in vibration at 1X and 2X running speed mean?
The 1X component corresponds to the shaft's rotational frequency and is often characteristic of unbalance. The 2X component can appear with misalignment or other non-linear mechanical phenomena, among other causes. Neither 1X nor 2X is a diagnosis on its own. We interpret them together with phase measurements, the other spectral components and the operating conditions to determine the likely cause of vibration in a rotating machine.
What are the symptoms of rolling-element and fluid-film bearing damage?
In rolling-element bearings, signs of damage can include characteristic defect frequencies, increased high-frequency vibration energy and changes in the signal envelope. In fluid-film bearings we analyse relative shaft vibration, orbits, journal centreline position and subsynchronous phenomena, among other things. The choice of diagnostic method depends on the bearing type, machine speed and the measurement system available.
How can rotor unbalance be distinguished from mechanical resonance?
With unbalance, the response at the rotational frequency (1X) usually dominates. Near a resonance, amplitude can rise sharply as speed changes, and the vibration phase shifts markedly. Measurements during run-up or coast-down, amplitude and phase plots, and analysis of the system's natural frequencies are therefore helpful. A spectrum taken at a single operating point may not be enough.
What does a sudden increase in turbine, pump or compressor vibration mean?
A sudden increase in vibration calls for checking whether the process conditions, speed, load or mechanical condition of the machine have changed. Possible causes include damage to rotor components, changes in bearing operating conditions, looseness or adverse flow phenomena. We analyse trends, spectra, alarms and process parameters together. The decision on whether to keep the machine running is made by the operators in line with the operating instructions and protection thresholds.
What is the difference between vibration measurement and vibration diagnostics?
Vibration measurement gives you data on the level and character of vibration. Diagnostics is the interpretation of that data: identifying the cause, assessing the machine's condition and recommending corrective action.
Can you work with data from our monitoring system?
Yes. We analyse data from online monitoring systems already in service and, where needed, supplement it with our own on-site measurements.
Need a diagnosis or a quote?
Basic machine data and a short description are enough.