Skip to content

Machinery vibration diagnostics

We assess the condition of rotating machinery by measuring and analysing vibration signals.

The goal is not just to quantify vibration levels, but to pinpoint their root cause and recommend specific corrective actions. Our vibration analysts hold ISO 18436‑2 Category III certification.

Scope

What we offer

We work with data from online monitoring systems as well as our own on-site measurements taken with portable instruments. Every diagnosis ends with a report setting out our findings and recommendations.

  • Spectrum and phase analysis
  • Shaft orbits and shaft centreline position
  • Run-up and coast-down analysis
  • Post-overhaul and acceptance diagnostics
  • Analysis of online monitoring data
  • Report with findings and recommendations

When to call us

Typical symptoms

  • Rising vibration

    The trend keeps climbing with no obvious process cause.

  • Alarms and trips

    Protection trips or frequent alarms from the MMS.

  • Vibration after an overhaul

    The machine runs worse after the overhaul than before it.

  • Start-up problems

    High vibration when passing through critical speeds.

  • Bearing noise and temperature

    Unusual noise or rising bearing temperatures.

  • Spectrum changes

    New components in the spectrum or a shift in 1X phase.

Recognise one of these symptoms? An analyst will help find the cause.

Analysis tools

Methods and analyses

  • Spectrum analysis

    Identifying frequency components and tracing their sources.

  • Phase and orbit analysis

    Assessing shaft motion, unbalance, misalignment and looseness.

  • Transient analysis

    Bode, polar and waterfall plots from run-ups and coast-downs.

  • Trends and process correlation

    Relating vibration to load, temperature and operating parameters.

Process

How we work together

  1. 01

    Request

    Problem description, machine data, available measurements.

  2. 02

    Data review

    Review of trends and MMS data, where available.

  3. 03

    On-site measurements

    Supplementary measurements, including transient conditions.

  4. 04

    Diagnosis

    Identifying the root cause of the vibration.

  5. 05

    Report and recommendations

    Findings, recommended actions and support in carrying them out.

From the field

Related projects

  • 2026

    TAURON, Czchów hydropower plant · Poland

    Coupling alignment checks on the flap gate drives during their modernisation.

  • 2026

    TAURON, Otmuchów hydropower plant · Poland

    Independent vibration measurements on a hydro unit before its overhaul, as reference data for the overhaul.

  • 2026

    ORLEN Termika – Żerań CHP · Poland

    Assessment of the dynamic condition of turbine set TZ13 under the protection-systems frame agreement.

  • 2026

    ORLEN Termika Silesia, Wodzisław Śląski · Poland

    Diagnostics of 11 fans in Wodzisław and 4 at the Niewiadom branch, with balancing, alignment and acceptance.

  • 2026

    ORLEN Termika Silesia – Żory and Czerwionka-Leszczyny · Poland

    Diagnostics and service of 14 fans at two plants, including acceptance for operation.

  • 2026

    ORLEN Termika Silesia, Wodzisław Śląski (formerly PGNiG Termika EP) · Poland

    Diagnostics of 11 fans with balancing, alignment and acceptance for operation.

  • 2025

    Enefit – Balti Power Plant · Estonia

    Dynamic condition of the LMZ K-200-130 turbine set, unit 11, analysed during overhaul and start-up, with recommendations.

  • 2025

    Bhotekoshi Power Company · Nepal

    Vibration data of a 22.5 MW turbine-generator analysed: condition, recommendations and expected remaining service life.

Frequently asked questions

Didn't find your answer? Ask an engineer →

How long does vibration diagnostics of industrial machinery take?

Basic vibration measurements and an initial assessment of the problem are usually completed in a single site visit. Diagnostics of turbines, compressors, pumps and other critical rotating machines may require spectrum and phase analysis and measurements at different loads. When the report is delivered depends on the scope of the work.

Can vibration diagnostics be carried out without stopping the machine?

Yes. We usually measure vibration on rotating machinery during normal operation, as this shows how the machine behaves under real operating conditions. Where justified, measurements during run-up, coast-down or load changes are also needed. Safe access to the measurement points is agreed with the plant.

What faults can vibration diagnostics detect?

Vibration analysis helps identify the symptoms of rotor unbalance, misalignment, mechanical looseness, bearing damage, gearbox problems and some resonance phenomena. For turbines and compressors we also take rotor dynamics and the influence of process parameters into account. A final assessment requires the data to be interpreted in the context of the specific machine.

Is vibration spectrum analysis enough to establish the cause of a failure?

Not always. Spectrum analysis is the foundation of vibration diagnostics, but similar symptoms can have different causes. That is why we combine frequency analysis with phase measurements, vibration trends, operating data and, where needed, run-up or coast-down characteristics. This reduces the risk of a wrong diagnosis.

What does a machine vibration diagnostics report contain?

Depending on the agreed scope, a vibration report contains the measurement results, spectra and vibration characteristics, an assessment of the machine's condition and a description of the abnormalities found. We also give conclusions and recommendations on continued operation, further testing or service work. For critical machines, comparison with earlier measurements is important.

What are the most common causes of high vibration in rotating machinery?

High vibration in rotating machinery can result from unbalance, shaft misalignment, mechanical looseness, bearing damage, resonance or unstable process conditions. In turbines and compressors, rotor-dynamic phenomena also play a part. The cause is determined from vibration spectra, phase and trends together with operating parameters. A rise in the overall vibration level alone does not point to a single fault.

Need a diagnosis or a quote?

Basic machine data and a short description are enough.