From vibration measurements to condition assessment based on electrical parameters.
Symptoms
Typical problems
Bearing damage
Rising bearing vibration and temperature.
Rotor cage damage
Broken bars, sidebands in the current spectrum.
Air-gap eccentricity
Magnetic asymmetry, components at twice line frequency.
Misalignment with the driven machine
2X components and axial vibration.
Power supply issues
Voltage unbalance, harmonics.
Services and parts
What we do
- 01
Electric motor monitoring
Condition assessment from currents and voltages.
- 02
Vibration measurements
Vibration measurements on motors and generators.
- 03
Vibration diagnostics
Separating mechanical from electrical root causes.
- 04
Laser shaft alignment
Alignment with the driven machine.
- 05
Machine balancing
Rotor balancing.
Related projects
2025
Volkswagen Poznań – Września plant · Poland
Vibration measurements on 28 electric motors with a diagnostic report and recommended repairs or operating changes.
2024
Food & beverage plant, Poland
Vibration monitoring installed on the generator of an engine-driven generating set to assess its dynamic condition.
2017
Veolia Energia Poznań – Karolin CHP · Poland
Vibration monitoring of turbogenerator TG1 extended with end-winding vibration measurements.
Frequently asked questions
Didn't find your answer? Ask an engineer →
How does monitoring based on electrical parameters work?
The system analyses the motor's supply currents and voltages and uses them to assess the condition of the motor and the driven machine — without fitting vibration sensors to the casing.
Do you diagnose generators?
Yes — vibration, shaft position and bearing condition, including as part of a turbine-generator or hydro unit.
Need a diagnosis or a quote?
Basic machine data and a short description are enough.