Symptoms
Typical problems
Cavitation
Noise, broadband vibration, impeller erosion.
Rolling-element bearing damage
Bearing defect frequencies in the spectrum.
Misalignment with the driver
2X components, high axial vibration.
Impeller unbalance
Dominant 1X component.
Structural resonance
Vibration amplified at a particular speed.
Seal wear
Leaks and rising temperature.
Services and parts
What we do
- 01
Vibration measurements
Pump condition assessment and acceptance measurements.
- 02
Vibration diagnostics
Finding the root cause of vibration.
- 03
Machine balancing
On-site impeller and rotor balancing.
- 04
Laser shaft alignment
Aligning the pump with its motor.
- 05
Online condition monitoring
Monitoring of critical and auxiliary pumps.
- 06
Pump overhauls
Pump overhauls and refurbishment.
- 07
Spare parts
Pump parts, including components reproduced by reverse engineering.
Related projects
2026
TAURON, Nowe Jaworzno power plant · Poland
Pump monitoring on the 910 MW unit upgraded: Orbit 60 supplied, installed, configured and commissioned on feed pumps.
2025
Rafineria Gdańska, Gdańsk refinery · Poland
Orbit 60 system supplied for pumps 1010-P78 and 1010-P79.
2025
Rafineria Gdańska, Gdańsk refinery · Poland
Upgrade of the machinery monitoring system for the pump units P8A+P1A and P8B+P1B at Unit 100.
2024
Rafineria Gdańska, Gdańsk refinery · Poland
Design and supply of two machinery monitoring cabinets for six pumps (P37, P79, P80, P1A, P1B, P27).
2020
ORLEN, Płock refinery · Poland
Upgrade of the special measurement system of pump P-103B at the HOG unit.
2018
ORLEN, Płock refinery · Poland
Upgrade of the machinery monitoring system at the DRW-3 unit: 36 pump sets.
2017
Grupa LOTOS, Gdańsk refinery · Poland
Vibration measurement system for pump units: supply and commissioning.
Frequently asked questions
Didn't find your answer? Ask an engineer →
Do you diagnose cavitation?
Yes. We identify cavitation from the character of the vibration spectrum and the pump's operating parameters, and point to the likely process causes.
Can pumps be monitored without fitting vibration sensors?
For electrically driven pumps, yes — through monitoring based on the motor's electrical parameters.
Need a diagnosis or a quote?
Basic machine data and a short description are enough.