From vibration amplitude and phase measurements we calculate the mass correction needed to reduce vibration caused by unbalance — without removing the rotor, provided the machine's design and condition allow it.
Scope
What we offer
Before balancing, we confirm that unbalance really is the cause of the vibration — rather than misalignment, looseness or resonance, for example. We finish balancing with a check measurement and a report as standard.
- Single- and two-plane balancing
- In-situ balancing without removing the rotor
- Measurement of initial and final condition
- Selection of trial and correction weights
- Verifying the cause of vibration before correction
- Report with before-and-after results
When to call us
Typical situations
Dominant 1X component
High vibration at running speed.
Rotor deposits
Uneven build-up on fan blades.
After part replacement
New blades, coupling or other rotating parts.
After rotor repair
Vibration up after a repair or refurbishment.
Gradual change
Vibration creeping up due to erosion or wear.
New machine
Vibration above specification at acceptance.
Recognise one of these symptoms? An analyst will help find the cause.
Method
How we balance
Baseline measurement
Vibration amplitude and phase at the measurement points.
Trial weight
Determining the influence coefficients.
Correction
Fitting the correction weight at the calculated position.
Verification
Final measurement and a trim correction if needed.
Process
How we work together
- 01
Request
Machine type, speed, access to the rotor.
- 02
Root-cause check
Confirming that unbalance is the cause.
- 03
Balancing
Measurements, trial weight, correction.
- 04
Final measurement
Confirming the result.
- 05
Report
Before-and-after results, recommendations.
Projects
Related projects
2026
ORLEN Termika Silesia, Wodzisław Śląski · Poland
Diagnostics of 11 fans in Wodzisław and 4 at the Niewiadom branch, with balancing, alignment and acceptance.
2026
ORLEN Termika Silesia, Wodzisław Śląski (formerly PGNiG Termika EP) · Poland
Diagnostics of 11 fans with balancing, alignment and acceptance for operation.
2025
ORLEN Termika Silesia, Wodzisław Śląski · Poland
Diagnostics of 11 fans with balancing, alignment and acceptance for operation.
2023–2024
Nowa Czechnica CHP, Siechnice · Poland
Bently Nevada machinery monitoring system for 9 balance-of-plant rotating machines of the new CHP plant.
2023
Ignitis gamyba – Elektrėnai Power Plant · Lithuania
Unit 8: balance quality of the LP and IP rotors of a K-300-240 turbine and TVV-320-2 generator verified, with recommendations.
2018
AB Achema, Jonava · Lithuania
Rotor for steam turbine A-4601: documentation, manufacture, NDT, thermal stability tests, balancing and speed tests.
2015
ANWIL, Włocławek · Poland
Turbine rotor T-1403: NDT, thermal stability tests, balancing and low- and high-speed measurements.
Related services
Typical machines
Other rotating machinery — e.g. wind turbines, gearboxes. Ask us →
Frequently asked questions
Didn't find your answer? Ask an engineer →
How long does on-site balancing of a rotor or fan take?
A simple balancing job on a rotor in the machine's own bearings can sometimes be completed within one shift. The time depends on access to the correction planes, the number of trial runs and the dynamic behaviour of the system. Before balancing, we check whether the high vibration is really caused by unbalance and not, for example, by misalignment or looseness.
Can a rotor be balanced without dismantling the machine?
Yes. On-site dynamic balancing is often carried out in the machine's own bearings, without removing the rotor. This approach is used for fans, blowers and selected drive trains, among others. It requires safe access to the mass correction points and the ability to take measurements while the machine is running.
Does balancing eliminate every cause of high vibration?
No. Rotor balancing helps when unbalance is the main source of vibration. A similar increase in vibration can also be caused by damaged bearings, shaft misalignment, looseness, resonance or unstable operating conditions. That is why we recommend vibration diagnostics and identifying the cause of the problem before any mass correction.
What are the symptoms of unbalance in an industrial fan impeller?
Fan unbalance often causes increased vibration at the rotational frequency (1X), particularly after deposits build up on the blades or the impeller's mass changes. The symptoms may become more pronounced as speed increases. However, it should not be assumed that every increase in vibration means balancing is needed. Before correcting the mass, we also check the condition of the bearings and mountings, looseness and possible resonance.
What is the difference between static and dynamic balancing?
Static balancing corrects the unbalance caused by the centre of mass being offset from the axis of rotation. Dynamic balancing takes into account how the unbalance is distributed along the rotor and may require correction in more than one plane. The choice of method depends on the rotor's design, geometric proportions and operating speed. For many industrial rotors a dynamic assessment is necessary.
What do balance quality grades G2.5 and G6.3 under ISO 21940 mean?
G2.5 and G6.3 designate balance quality grades for rigid rotors in the ISO 21940 series. A grade defines how the permissible residual unbalance depends on rotational speed; it is not a universal bearing vibration limit. The required grade is chosen to suit the type of rotor and its operating conditions. The balancing result should be interpreted together with the manufacturer's tolerances and the method of verification.
Why does vibration remain high after rotor balancing?
If vibration is still high after balancing, the problem may lie in misalignment, mechanical looseness, resonance, a damaged bearing or process-related phenomena. The conditions under which the mass correction was made also matter. Further diagnostics should compare spectra, phase and operating parameters before and after balancing. A further mass correction without establishing the cause can prove ineffective.
How is balancing different from alignment?
Balancing corrects an uneven mass distribution in the rotor. Alignment corrects the relative position of shafts joined by a coupling. They address different causes of vibration and are different services — which is why we verify the cause before balancing.
Need a diagnosis or a quote?
Basic machine data and a short description are enough.