Skip to content

On-site machine balancing

We balance rotors where the machine operates.

From vibration amplitude and phase measurements we calculate the mass correction needed to reduce vibration caused by unbalance — without removing the rotor, provided the machine's design and condition allow it.

Scope

What we offer

Before balancing, we confirm that unbalance really is the cause of the vibration — rather than misalignment, looseness or resonance, for example. We finish balancing with a check measurement and a report as standard.

  • Single- and two-plane balancing
  • In-situ balancing without removing the rotor
  • Measurement of initial and final condition
  • Selection of trial and correction weights
  • Verifying the cause of vibration before correction
  • Report with before-and-after results

When to call us

Typical situations

  • Dominant 1X component

    High vibration at running speed.

  • Rotor deposits

    Uneven build-up on fan blades.

  • After part replacement

    New blades, coupling or other rotating parts.

  • After rotor repair

    Vibration up after a repair or refurbishment.

  • Gradual change

    Vibration creeping up due to erosion or wear.

  • New machine

    Vibration above specification at acceptance.

Recognise one of these symptoms? An analyst will help find the cause.

Method

How we balance

  • Baseline measurement

    Vibration amplitude and phase at the measurement points.

  • Trial weight

    Determining the influence coefficients.

  • Correction

    Fitting the correction weight at the calculated position.

  • Verification

    Final measurement and a trim correction if needed.

Process

How we work together

  1. 01

    Request

    Machine type, speed, access to the rotor.

  2. 02

    Root-cause check

    Confirming that unbalance is the cause.

  3. 03

    Balancing

    Measurements, trial weight, correction.

  4. 04

    Final measurement

    Confirming the result.

  5. 05

    Report

    Before-and-after results, recommendations.

Mining · 2024

Trim balancing of fans at a coal mine

Coal mine, Poland

  • Machine balancing
  • Vibration measurements
  • Vibration diagnostics
Read case study

Related projects

  • 2026

    ORLEN Termika Silesia, Wodzisław Śląski · Poland

    Diagnostics of 11 fans in Wodzisław and 4 at the Niewiadom branch, with balancing, alignment and acceptance.

  • 2026

    ORLEN Termika Silesia, Wodzisław Śląski (formerly PGNiG Termika EP) · Poland

    Diagnostics of 11 fans with balancing, alignment and acceptance for operation.

  • 2025

    ORLEN Termika Silesia, Wodzisław Śląski · Poland

    Diagnostics of 11 fans with balancing, alignment and acceptance for operation.

  • 2023–2024

    Nowa Czechnica CHP, Siechnice · Poland

    Bently Nevada machinery monitoring system for 9 balance-of-plant rotating machines of the new CHP plant.

  • 2023

    Ignitis gamyba – Elektrėnai Power Plant · Lithuania

    Unit 8: balance quality of the LP and IP rotors of a K-300-240 turbine and TVV-320-2 generator verified, with recommendations.

  • 2018

    AB Achema, Jonava · Lithuania

    Rotor for steam turbine A-4601: documentation, manufacture, NDT, thermal stability tests, balancing and speed tests.

  • 2015

    ANWIL, Włocławek · Poland

    Turbine rotor T-1403: NDT, thermal stability tests, balancing and low- and high-speed measurements.

Frequently asked questions

Didn't find your answer? Ask an engineer →

How long does on-site balancing of a rotor or fan take?

A simple balancing job on a rotor in the machine's own bearings can sometimes be completed within one shift. The time depends on access to the correction planes, the number of trial runs and the dynamic behaviour of the system. Before balancing, we check whether the high vibration is really caused by unbalance and not, for example, by misalignment or looseness.

Can a rotor be balanced without dismantling the machine?

Yes. On-site dynamic balancing is often carried out in the machine's own bearings, without removing the rotor. This approach is used for fans, blowers and selected drive trains, among others. It requires safe access to the mass correction points and the ability to take measurements while the machine is running.

Does balancing eliminate every cause of high vibration?

No. Rotor balancing helps when unbalance is the main source of vibration. A similar increase in vibration can also be caused by damaged bearings, shaft misalignment, looseness, resonance or unstable operating conditions. That is why we recommend vibration diagnostics and identifying the cause of the problem before any mass correction.

What are the symptoms of unbalance in an industrial fan impeller?

Fan unbalance often causes increased vibration at the rotational frequency (1X), particularly after deposits build up on the blades or the impeller's mass changes. The symptoms may become more pronounced as speed increases. However, it should not be assumed that every increase in vibration means balancing is needed. Before correcting the mass, we also check the condition of the bearings and mountings, looseness and possible resonance.

What is the difference between static and dynamic balancing?

Static balancing corrects the unbalance caused by the centre of mass being offset from the axis of rotation. Dynamic balancing takes into account how the unbalance is distributed along the rotor and may require correction in more than one plane. The choice of method depends on the rotor's design, geometric proportions and operating speed. For many industrial rotors a dynamic assessment is necessary.

What do balance quality grades G2.5 and G6.3 under ISO 21940 mean?

G2.5 and G6.3 designate balance quality grades for rigid rotors in the ISO 21940 series. A grade defines how the permissible residual unbalance depends on rotational speed; it is not a universal bearing vibration limit. The required grade is chosen to suit the type of rotor and its operating conditions. The balancing result should be interpreted together with the manufacturer's tolerances and the method of verification.

Need a diagnosis or a quote?

Basic machine data and a short description are enough.