Trim balancing of fans at a coal mine

Fans at a coal mine were running with elevated vibration. Measurements and analysis confirmed unbalance; after trim balancing on site, vibration was within the limits of the applicable standard.

Project details

Client
Coal mine, Poland
Industry
Mining
Location
Poland
Year
2024
  1. 01

    Challenge

    Fans at a coal mine were running with elevated vibration. The cause had to be identified and the vibration brought back within acceptable limits.

  2. 02

    Scope of work

    • Vibration measurements on the fans
    • Analysis of the measurement data
    • Trim balancing on site
    • Check measurements after balancing
  3. 03

    Solution

    We started with vibration measurements on the fans. Analysis of the data confirmed unbalance as the cause of the elevated vibration.

    We then trim-balanced the fans on site, without removing the rotors, and repeated the measurements to confirm the effect.

  4. 04

    Results

    • Cause of the elevated vibration identified: unbalance
    • Fans trim-balanced on site
    • Vibration within the limits of the applicable standard

Equipment and technologies

  • Portable vibration measuring system
  • Fan drive motor
  • Drive of another fan; labels blurred

Need a diagnosis or a quote?

Basic machine data and a short description are enough.