Project details
- Client
- Coal mine, Poland
- Industry
- Mining
- Location
- Poland
- Year
- 2024
- 01
Challenge
Fans at a coal mine were running with elevated vibration. The cause had to be identified and the vibration brought back within acceptable limits.
- 02
Scope of work
- Vibration measurements on the fans
- Analysis of the measurement data
- Trim balancing on site
- Check measurements after balancing
- 03
Solution
We started with vibration measurements on the fans. Analysis of the data confirmed unbalance as the cause of the elevated vibration.
We then trim-balanced the fans on site, without removing the rotors, and repeated the measurements to confirm the effect.
- 04
Results
- Cause of the elevated vibration identified: unbalance
- Fans trim-balanced on site
- Vibration within the limits of the applicable standard
Equipment and technologies
- Portable vibration measuring system
Gallery
Fan drive motor Drive of another fan; labels blurred
Related services
Need a diagnosis or a quote?
Basic machine data and a short description are enough.