Recurring fan bearing failures at a cement plant

The bearings of a fan had to be replaced every few weeks. Alignment, vibration measurements and analysis showed the cause: a large axial force on bearings not designed to carry it.

Project details

Client
Cement plant, Poland
Location
Poland
Year
2024
  1. 01

    Challenge

    The client reported that the fan bearings had to be replaced every few weeks. Replacing the bearings alone did not solve the problem.

  2. 02

    Scope of work

    • Shaft alignment of the fan drive
    • Vibration measurements with observation of bearing temperature
    • Analysis of the measurement data
    • Check of the components used
  3. 03

    Solution

    We started with shaft alignment and vibration measurements. During the measurements the vibration and temperature of one bearing rose steadily.

    Detailed analysis of the data and a check of the components used showed a significant axial force acting on bearings that were not designed to carry axial loads. This force was what degraded them.

  4. 04

    Results

    • Root cause identified: axial force on bearings not suited to axial load
    • Fan drive aligned
    • A basis for remedial action instead of further bearing replacements

Equipment and technologies

  • Shaft alignment equipment
  • Portable vibration measuring system
  • Measuring equipment set up next to the fan