Project details
- Client
- Cement plant, Poland
- Industry
- Heavy industry & manufacturing
- Location
- Poland
- Year
- 2024
- 01
Challenge
The client reported that the fan bearings had to be replaced every few weeks. Replacing the bearings alone did not solve the problem.
- 02
Scope of work
- Shaft alignment of the fan drive
- Vibration measurements with observation of bearing temperature
- Analysis of the measurement data
- Check of the components used
- 03
Solution
We started with shaft alignment and vibration measurements. During the measurements the vibration and temperature of one bearing rose steadily.
Detailed analysis of the data and a check of the components used showed a significant axial force acting on bearings that were not designed to carry axial loads. This force was what degraded them.
- 04
Results
- Root cause identified: axial force on bearings not suited to axial load
- Fan drive aligned
- A basis for remedial action instead of further bearing replacements
Equipment and technologies
- Shaft alignment equipment
- Portable vibration measuring system
Gallery
Measuring equipment set up next to the fan
Related services
Need a diagnosis or a quote?