Steam and gas turbine overhauls

Together with specialist partners, we overhaul steam and gas turbines.

From inspection and non-destructive testing to repairs, assembly and start-up support. The scope of work is matched to the turbine's condition and the length of the outage.

Scope

What the service covers

We plan the overhaul from the operating history, diagnostic data and inspection results, so that the scope of work reflects the machine's actual condition.

  • Inspection and condition assessment of components
  • Non-destructive testing (NDT)
  • Repair and refurbishment of turbine components
  • Clearance and dimensional measurements
  • Assembly, alignment and balancing
  • Start-up support and post-overhaul measurements

When to call us

Typical situations

  • Scheduled overhaul

    Inspection due after reaching the operating hours or starts limit.

  • Rising vibration

    Changes in condition confirmed by diagnostics.

  • Lower efficiency

    Deteriorating turbine performance.

  • Component damage

    Cracks, erosion or wear found.

  • After a failure

    Assessing the damage and returning the turbine to service.

  • Short outage

    Work must fit into a limited outage window.

Recognise one of these symptoms? An analyst will help find the cause.

Outcome

What you get

  • Condition-based scope

    Work driven by inspection and diagnostics.

  • Test results

    Inspection, NDT and measurement records.

  • An overhauled turbine

    Assembled, checked and started up.

  • Overhaul documentation

    A record of the work done and operating recommendations.

Process

How we work together

  1. 01

    Request

    Turbine type, history, outage date.

  2. 02

    Preparation

    Data review, initial scope, schedule.

  3. 03

    Disassembly and inspection

    Condition assessment, NDT, measurements.

  4. 04

    Repairs and assembly

    Work arising from the inspection, assembly.

  5. 05

    Start-up

    Start-up support, measurements, documentation.

Frequently asked questions

Didn't find your answer? Ask an engineer →

Do you take vibration measurements on turbines after an overhaul?

Yes. Vibration diagnostics during the start-up of a steam or gas turbine makes it possible to assess how the rotor system behaves after the overhaul work. We analyse vibration levels, their character and how they change with speed and load. The results serve as input for assessing the dynamic condition and as a baseline for later operational checks.

Do you support the start-up of rotating machinery after an overhaul?

Yes. Depending on the order, diagnostic support for rotating machinery start-ups covers monitoring vibration as speed increases, as operation stabilises and as the load changes. The measurements help catch abnormalities after the overhaul of a turbine, compressor, pump or drive train. We tailor the scope of testing to the machine's design and the site's procedures.

What are the most common causes of high vibration in a steam turbine?

High vibration in a steam turbine can result from rotor unbalance, misalignment, fluid-film bearing problems, thermal distortion or dynamic phenomena at certain speeds. Changes in steam conditions and the state of the machine after an overhaul also matter. Diagnostics includes analysis of shaft and bearing vibration, phase, orbits and run-up data. The cause should not be determined from a single amplitude value.

How can dynamic instability of a turbine or compressor rotor be recognised?

Dynamic instability can show up as increased subsynchronous vibration, changes in shaft orbits and a sharp response to certain operating conditions. In turbine or compressor diagnostics, spectra, phase and the shaft trajectory are analysed, along with how the symptoms depend on speed, load and bearing parameters. Detecting a subsynchronous component is not enough on its own to identify the cause: the whole rotor system needs to be assessed.

What are oil whirl and oil whip in fluid-film bearings?

Oil whirl is a self-excited subsynchronous vibration linked to the dynamics of the oil film in a fluid-film bearing. In oil whip, the instability can couple with one of the rotor's natural modes, and the response frequency stays roughly the same despite changes in speed. Diagnosing them requires spectra, shaft orbits and operating data. Both situations call for specialist analysis of the rotor–bearing system.

What diagnostic measurements are taken during a turbine overhaul?

The scope of turbine diagnostics during an overhaul and the start-up that follows depends on the work carried out. It may include assessment of the bearing system, alignment measurements and sensor checks and, after start-up, analysis of shaft and bearing housing vibration. Start-up measurements make it easier to compare the dynamic characteristics with the condition before the overhaul. The results are documented in line with the agreed acceptance procedure.

Need a diagnosis or a quote?

Basic machine data and a short description are enough.