Skip to content

Fans & blowers

Balancing, measurements, diagnostics and alignment for fans and blowers — including large flue gas fans.

Symptoms

Typical problems

  • Impeller build-up and erosion

    Unbalance that grows over time.

  • Mechanical and foundation looseness

    Running-speed harmonics, unstable phase.

  • Bearing damage

    Rising high-frequency vibration.

  • Structural resonance

    Vibration amplified as speed changes.

  • Misalignment

    2X components, axial vibration.

Related projects

  • 2026

    ORLEN Termika Silesia, Wodzisław Śląski · Poland

    Diagnostics of 11 fans in Wodzisław and 4 at the Niewiadom branch, with balancing, alignment and acceptance.

  • 2026

    ORLEN Termika Silesia – Żory and Czerwionka-Leszczyny · Poland

    Diagnostics and service of 14 fans at two plants, including acceptance for operation.

  • 2026

    ORLEN Termika Silesia, Wodzisław Śląski (formerly PGNiG Termika EP) · Poland

    Diagnostics of 11 fans with balancing, alignment and acceptance for operation.

  • 2025

    TAURON, Nowe Jaworzno power plant · Poland

    Upgrade of the measurement and vibration diagnostic systems for the fans of the 910 MW unit.

  • 2025

    Volkswagen Poznań – Września plant · Poland

    Condition diagnostics of 28 industrial fan drives.

  • 2025

    ORLEN Termika Silesia, Wodzisław Śląski · Poland

    Diagnostics of 11 fans with balancing, alignment and acceptance for operation.

  • 2019

    PGE GiEK – Bełchatów Power Plant · Poland

    Diagnostics of the induced-draft fan drive (motor and fan) of the 858 MW unit II.

Frequently asked questions

Didn't find your answer? Ask an engineer →

How often should industrial fans be balanced?

How often a fan needs balancing depends on its design, operating conditions and how quickly contamination builds up on the impeller. Rather than a fixed schedule, periodic vibration measurements and trend analysis are advisable. Before balancing, the condition of the blades, any deposits and other potential causes of vibration should be checked. The decision to correct the mass is based on diagnostics.

Do you balance large fans on site?

Yes. We balance in situ without removing the impeller, provided the machine's technical condition allows it.

Need a diagnosis or a quote?

Basic machine data and a short description are enough.