Symptoms
Typical problems
Impeller build-up and erosion
Unbalance that grows over time.
Mechanical and foundation looseness
Running-speed harmonics, unstable phase.
Bearing damage
Rising high-frequency vibration.
Structural resonance
Vibration amplified as speed changes.
Misalignment
2X components, axial vibration.
Services and parts
What we do
Projects on this machine type
Heavy industry & manufacturing · 2024
Recurring fan bearing failures at a cement plant
Cement plant, Poland
- Vibration diagnostics
- Laser shaft alignment
- Vibration measurements
Mining · 2024
Trim balancing of fans at a coal mine
Coal mine, Poland
- Machine balancing
- Vibration measurements
- Vibration diagnostics
Related projects
2026
ORLEN Termika Silesia, Wodzisław Śląski · Poland
Diagnostics of 11 fans in Wodzisław and 4 at the Niewiadom branch, with balancing, alignment and acceptance.
2026
ORLEN Termika Silesia – Żory and Czerwionka-Leszczyny · Poland
Diagnostics and service of 14 fans at two plants, including acceptance for operation.
2026
ORLEN Termika Silesia, Wodzisław Śląski (formerly PGNiG Termika EP) · Poland
Diagnostics of 11 fans with balancing, alignment and acceptance for operation.
2025
TAURON, Nowe Jaworzno power plant · Poland
Upgrade of the measurement and vibration diagnostic systems for the fans of the 910 MW unit.
2025
Volkswagen Poznań – Września plant · Poland
Condition diagnostics of 28 industrial fan drives.
2025
ORLEN Termika Silesia, Wodzisław Śląski · Poland
Diagnostics of 11 fans with balancing, alignment and acceptance for operation.
2019
PGE GiEK – Bełchatów Power Plant · Poland
Diagnostics of the induced-draft fan drive (motor and fan) of the 858 MW unit II.
Frequently asked questions
Didn't find your answer? Ask an engineer →
How often should industrial fans be balanced?
How often a fan needs balancing depends on its design, operating conditions and how quickly contamination builds up on the impeller. Rather than a fixed schedule, periodic vibration measurements and trend analysis are advisable. Before balancing, the condition of the blades, any deposits and other potential causes of vibration should be checked. The decision to correct the mass is based on diagnostics.
Do you balance large fans on site?
Yes. We balance in situ without removing the impeller, provided the machine's technical condition allows it.
Need a diagnosis or a quote?
Basic machine data and a short description are enough.