Operators see machine measurements, statuses and alarms where they run the process, and the data reaches historian and analytics systems.
Scope
What the service covers
We carry out integration together with the site's automation team or the control system contractor, based on an agreed signal list.
- Agreeing the signal list and data exchange method
- OPC and Modbus communication setup
- Hardwired signals: analogue and relay outputs
- Mapping of measurements, statuses and alarms
- Communication tests and value verification
- Interface documentation
When to call us
Typical situations
Data only available locally
Machine data visible only in the cabinet or MMS software.
New control system
A DCS migration requires reconnecting the MMS.
MMS upgrade
A new monitoring system must be connected to the existing DCS.
Inconsistent values
Differences between MMS and control system readings.
Need for history
Machine data should go to the historian.
No documentation
Unknown or outdated signal list.
Recognise one of these symptoms? An analyst will help find the cause.
Outcome
What you get
Working communication
Measurements, statuses and alarms available in the control system.
Verified values
MMS and control system readings that match.
Signal list
An up-to-date description of all the data exchanged.
Interface documentation
The basis for further maintenance and changes.
Process
How we work together
- 01
Request
Systems to connect, expected data scope.
- 02
Agreement
Signal list, protocol, split of tasks.
- 03
Configuration
Communication setup on the MMS side.
- 04
Testing
Checking transmission and values with the automation team.
- 05
Documentation
Interface description and signal list.
Projects
Related projects
2025
ORLEN Unipetrol RPA, Litvínov · Czech Republic
Service of 3500 and Trendmaster: new channels, alarms, relay logic and Modbus to the DCS and ESD configured; loop checks.
2019
ANWIL, Włocławek · Poland
Compressors C1601 and PC112 integrated into the diagnostic system.
2017
ORLEN Lietuva, Mažeikiai refinery · Lithuania
3500 monitoring for compressors IK-301 and IK-201: supply, installation, commissioning and System 1 integration.
Frequently asked questions
Didn't find your answer? Ask an engineer →
What data can be sent to the control system?
Usually measurement values, alarm and trip states, and the status of measurement chains and modules. The scope is set when the signal list is agreed.
Are trip functions sent over digital communication?
Machine trip signals are usually hardwired, through relay outputs. Digital communication is mainly used for measurements, statuses and alarms.
Who configures the control system side?
Usually the site's automation team or the DCS contractor. We agree the signal list with them and run the tests together.