The system continuously supervises critical parameters — vibration, axial position, rotational speed — and raises an alarm or a trip signal when limits are exceeded.
Scope
What the service covers
The scope is matched to the machine, its importance for the process and the site requirements. We handle both new installations and upgrades of systems already in service. We work with machinery protection systems designed to API 670 requirements, including Bently Nevada 3500 and Parker Meggitt VM600 (formerly Meggitt Vibro-Meter).
- Requirements analysis and measurement point selection
- Selection of sensors, modules and system structure
- Configuration of alarm limits and trip logic
- Installation of measurement chains and commissioning
- Functional testing of alarms and trips
- As-built documentation and staff training
When to call us
Typical situations
New critical machine
The installation needs continuous protection against damage.
Ageing system
No spare parts or support for the current hardware.
Spurious trips
Protection trips with no real cause in the machine.
New requirements
New standards or internal plant requirements.
Gaps in coverage
Only some of the critical points are supervised.
DCS integration
Alarms and statuses need to reach the control system.
Recognise one of these symptoms? An analyst will help find the cause.
Outcome
What you get
A working system
Protection configured and verified on site.
Verified limits
Alarm limits and trip logic agreed with the user.
Test records
Confirmation that measurement chains and protective functions work.
Documentation
Drawings, configuration and instructions for maintenance staff.
Process
How we work together
- 01
Request
Machine type, current protection, site requirements.
- 02
Concept
Measurement points, system structure, scope of work.
- 03
Design and supply
Documentation, hardware selection and preparation.
- 04
Installation and commissioning
Installation, configuration, functional tests.
- 05
Handover
Documentation, training, post-commissioning support.
Projects
Related projects
2026
AB Achema, Jonava · Lithuania
Modules for the existing 3500 protection systems.
2026
AB Achema, Jonava · Lithuania
Supply of a new Orbit 60 protection and vibration monitoring system.
2026
Enefit Power – Auvere Power Plant · Estonia
Spare parts for the 3500 protection system of the ALSTOM turbine.
2026
Ignitis gamyba – Elektrėnai Power Plant · Lithuania
Spare parts for the 3500 protection system.
2026
ORLEN Termika – Żerań and Siekierki CHP · Poland
Maintenance of the 3500 protection systems at both CHP plants under a frame agreement, ongoing since January 2026.
2026
ORLEN Termika – Żerań CHP · Poland
Assessment of the dynamic condition of turbine set TZ13 under the protection-systems frame agreement.
2025
AB Achema, Jonava · Lithuania
Spare parts for the 3500 protection systems.
2025
Eustream, gas compressor stations · Slovakia
Inventory and assessment of the protection and monitoring systems on gas-turbine-driven compressor units.
Related services
Typical machines
Other rotating machinery? Ask us →
Frequently asked questions
Didn't find your answer? Ask an engineer →
How is a protection system different from condition monitoring?
A protection system reacts when limits are exceeded and protects the machine from damage by raising an alarm or a trip signal. Condition monitoring collects and analyses data to detect changes in machine condition early. The two often work together.
Can a system be upgraded without replacing every sensor?
Often, yes. We check the condition and compatibility of the existing sensors and cabling, and replace only the parts that need it.
Can an upgrade be done during a short outage?
We plan the scope and schedule around the available outage window. Part of the work, such as cabinet prefabrication and testing, is done before the outage.
Need a diagnosis or a quote?
Basic machine data and a short description are enough.