Skip to content

PGE wind farms: online monitoring and bearing diagnostics

Since 2017 we have worked on PGE Energia Odnawialna's wind farms: online vibration monitoring on 39 GE 1.5 MW turbines, the diagnosis of squealing blade pitch bearings and, since 2025, remote condition monitoring.

Project details

Client
PGE Energia Odnawialna, wind farms, Poland
Industry
Wind / renewables
Location
Poland
Year
2017–2026

Key figures

GE 1.5 MW turbines with online monitoring
39
wind farms under remote monitoring
3
  1. 01

    Challenge

    In 2017–2019 we designed, supplied and installed online vibration monitoring on 39 GE 1.5 MW wind turbines at the Kisielice (27 turbines) and Koniecwałd (12 turbines) wind farms. Accelerometers sit on the gearbox and the generator, and a Bently Nevada 60M100 monitor in a field box in each nacelle sends the data over the network to the client's analysis server with Bently Nevada ADAPT Wind, where the client's diagnostics team works with it.

    In 2023 the client reported a different problem at one of its wind farms: the blade pitch bearings of its turbines squealed loudly, even when the bearings had been greased.

  2. 02

    Scope of work

    • Online monitoring (2017–2019): design, supply and installation of sensors on the gearbox and generator and of 60M100 monitors in nacelle field boxes
    • Installation and configuration of ADAPT Wind, commissioning and calibration of the measurement chain
    • Pitch bearings (2023): vibration measurements in the hub and nacelle, analysis of the data and review of the bearing design
    • Since July 2025: remote vibration monitoring and condition diagnostics of the Kisielice, Malbork and Karwice wind farms
  3. 03

    Solution

    For the pitch bearings we placed vibration sensors on the bearings and recorded data in the hub. The measurements confirmed the squealing.

    Analysis of the vibration data and of the bearing design showed a likely cause: because the blades move through very small angles, dents form in the bearing raceways, and in places the rolling elements slide over the raceway instead of rolling.

    Since July 2025 we have monitored the vibration of the turbines at the Kisielice, Malbork and Karwice wind farms remotely and assessed their condition.

  4. 04

    Results

    • 39 turbines at two wind farms with online vibration monitoring of the gearbox and generator, data on the client's analysis server
    • Pitch bearing squealing confirmed and recorded in the vibration measurements
    • Likely cause identified: raceway dents from very small pitch movements, with rolling elements sliding instead of rolling
    • Ongoing remote monitoring and condition diagnostics at three wind farms

Equipment and technologies

  • Bently Nevada 60M100
  • Bently Nevada ADAPT Wind
  • Accelerometers on gearbox and generator
  • Portable vibration measuring system
  • 60M100 in the nacelle field box
  • Accelerometer on the drive train
  • Sensors on the pitch bearing

Need a diagnosis or a quote?

Basic machine data and a short description are enough.